DOI | 10.1109/TIA.2022.3211251 |
ISSN | 0093-9994 |
Rótulo | lattes: 5932117211446307 1 MattosBoOsKoOlMo:2022:RoOpCu |
Chave de Citação | MattosBoOsKoOlMo:2022:RoOpCu |
Título | Robust Optimized Current Controller Based on a Two-Step Procedure for Grid-Connected Converters |
Ano | 2022 |
Data de Acesso | 06 maio 2024 |
Tipo de Trabalho | journal article |
Tipo Secundário | PRE PI |
Número de Arquivos | 1 |
Tamanho | 12048 KiB |
|
2. Contextualização | |
Autor | 1 Mattos, Everson 2 Borin, Lucas C. 3 Osorio, Caio R. D. 4 Koch, Gustavo G. 5 Oliveira, Ricardo C. L. F. 6 Montagner, Vinicius F. |
Grupo | 1 COESU-CGGO-INPE-MCTI-GOV-BR |
Afiliação | 1 Instituto Nacional de Pesquisas Espaciais (INPE) |
Endereço de e-Mail do Autor | 1 everson.mattos@gmail.com |
Revista | IEEE Transactions on Industry Applications |
Volume | 1 |
Páginas | 1-11 |
Nota Secundária | A1_ENGENHARIAS_IV A1_ENGENHARIAS_III B1_INTERDISCIPLINAR |
Histórico (UTC) | 2022-12-15 17:54:26 :: lattes -> administrator :: 2022 2023-01-04 11:50:06 :: administrator -> simone :: 2022 2023-01-04 17:26:36 :: simone -> administrator :: 2022 2023-01-23 17:06:37 :: administrator -> simone :: 2022 |
|
3. Conteúdo e estrutura | |
É a matriz ou uma cópia? | é a matriz |
Estágio do Conteúdo | concluido |
Transferível | 1 |
Tipo do Conteúdo | External Contribution |
Tipo de Versão | publisher |
Palavras-Chave | Grid-connected converter Hardware-in-the-loop Linear matrix inequalities Particle swarm optimization Proportional-resonant controller |
Resumo | Proportional-resonant controllers are largely used for grid-connected converters with LCL filters to ensure sinusoidal reference tracking and harmonic disturbance rejection. However, the design of such controllers becomes more difficult when it is necessary to ensure stability and suitable performance for converters operating under uncertain grid conditions, from stiff to weaker, and also when the number of resonants increases. In this more challenging scenario, available design procedures may lead to a poor tradeoff between transient and steady-state performances. To overcome this problem, this paper proposes an off-line automated control design procedure to obtain multiple robust optimized proportional-resonant controllers. The proposed procedure consists of two steps, where a particle swarm algorithm is used to obtain: i) the gains of an inner loop ensuring optimal active damping for the LCL filter resonance; ii) the gains of multiple proportional-resonant controllers by minimizing a tracking error index, taking into account uncertain grid impedance and control signal limits. The robust stability of the closed-loop system with the control gains tuned by the metaheuristics is certificated through a parameter-dependent Lyapunov function, constructed based on linear matrix inequalities. Several results from control Hardware-in-the-loop are presented for a case study, revealing that the proposal provides better performance in terms of reference tracking and disturbance rejection, when compared to similar control strategies from the literature. Experimental results from a prototype connected to the utility grid attest the practical feasibility of the proposed procedure. |
Área | ETES |
Arranjo | urlib.net > BDMCI > Fonds > Produção a partir de 2021 > CGGO > Robust Optimized Current... |
Conteúdo da Pasta doc | acessar |
Conteúdo da Pasta source | não têm arquivos |
Conteúdo da Pasta agreement | não têm arquivos |
|
4. Condições de acesso e uso | |
Idioma | pt |
Arquivo Alvo | Robust_Optimized_Current_Controller_Based_on_a_Two-Step_Procedure_for_Grid-Connected_Converters.pdf |
Grupo de Usuários | lattes |
Grupo de Leitores | administrator lattes simone |
Visibilidade | shown |
Permissão de Leitura | deny from all and allow from 150.163 |
Permissão de Atualização | não transferida |
|
5. Fontes relacionadas | |
Unidades Imediatamente Superiores | 8JMKD3MGPCW/46KUBT5 |
Lista de Itens Citando | sid.inpe.br/bibdigital/2022/04.03.22.35 4 |
URL (dados não confiáveis) | https://ieeexplore.ieee.org/document/9907862 |
Divulgação | SCOPUS |
Acervo Hospedeiro | dpi.inpe.br/plutao@80/2008/08.19.15.01 |
|
6. Notas | |
Notas | Setores de Atividade: Pesquisa e desenvolvimento científico. |
Campos Vazios | alternatejournal archivingpolicy archivist callnumber copyholder copyright creatorhistory descriptionlevel e-mailaddress format isbn lineage mark mirrorrepository month nextedition number orcid parameterlist parentrepositories previousedition previouslowerunit progress project resumeid rightsholder schedulinginformation secondarydate secondarykey session shorttitle sponsor subject tertiarymark tertiarytype |
|